FL-B101D40
Leopard Bargraph
A red, green or tri-color, 101 segment bargraph, with a 4-digit LED digital display for monitoring, measurement, and control applications, mounted in a 36x144 case.
|
 |
 |
|
-

- FL-B101D40 Leopard Bargraphs . . . PRICED FROM $200 to $350
-
A Smart Tricolor or mono-color digital bargraph with four fully programable set points for monitoring, measurement, and control applications
- Texmate, an international leader in Bargraphs and digital panel instruments for more than 20 years, introduces a new addition to our Leopard Family of meters. The FL-B101D40 bargraph is the optimal choice to replace switchboard, analog meters, or setpoint-controllers. Texmates state-of-the-art, user friendly technology, has produced a cost effective bargraph that is easy to program and calibrate, with more than 30 compatible modular signal conditioners that can be configured for almost any application.
-
- General Features
- External transmitters or signal conditioners can be eliminated by direct connection of the sensor output to more than 38 Plug-in Input Signal Conditioners that include:
AC/DC Current Pressure Resistance
AC/DC Voltage Process Temperature
Load Cell Prototype 4 to 20 mA
- Optional isolated 16 bit analog output. User or factory scalable to 4 to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span from ± one count to the full scale range of 1999 to 9999 (12000 counts).
- A Programable Tricolor (Red-Green-Orange) or mono color (red or green), 101 segment high brightness bargraph. Optional vertical or horizontal format.
- Red 4-digit LED display with a range of -1999 to 9999 (12000 counts). Optional green digital display.
- Front panel LED annunciators provide indication of setpoint status.
- Two 10 Amp Form C, and two 5 Amp Form A relays available
- Auto-sensing AC/DC power supply. For voltages between 85-265 V AC / 95-370 V DC (PS1) or 18-48 V AC / 10-72 V DC (PS2).
- 24 V DC excitation is available to power external 4/20mA transmitters and 5 or 10 V DC excitation is available for resistance bridge type sensors.
- Provision to connect an external programming lockout switch.
- Provision for external DIM switch to reduce the brightest display setting by 50%.
- Optional NEMA-4 front cover.
- Automatic intelligent averaging, smooths noisy signals while providing a fast display response to real level changes.
-
- Software Features
- Digital display and the 101 segment bargraph can be independently scaled.
- Bargraph center zero function.
- Four programmable setpoints.
- Adjustable delay-on-make and delay-on-break time for setpoints 1 and 2.
- Relay activation can be selected to occur above (HI) or below (LO) each setpoint.
- Digital display blanking.
- Decimal point setting.
- Four-level brightness control of bargraph, digital display, and setpoint LEDs.
-
- Specifications
- Input Specs: Depends on Input signal conditioner
- A/D Converter: 14 bit single slope
- Accuracy: ±(0.05% of reading + 2 counts)
- Temp. Coeff.: 100 ppm/°C (Typical)
- Warm up time: 2 minutes
- Conversion Rate: 10 conversions per second (Typical)
- Digital Display: 4 digit 0.31" LED red (std), green (optn) Range 1999 to 9999 counts.
- Bargraph Display: 101 segment 4 red vertical (std), green or tricolor (optn), horizontal (optn)
- Polarity: Assumed positive. Displays negative
- Decimal Selection: Front panel button selectable, XXXX
- Positive Overrange: Bargraph and top segments of digital display flash.
- Negative Overrange: First segment of bargraph and bottom segments of digital display flash.
- Relay Output: Two 5Amp Form A relays and Two 10 Amp Form C relays.
- Analog Output: Isolated 16 bit user scalable mA or V OIC (mA out) 4-20 mA @ 0 to 500 ohms max loop resistance OIV (volts out) 0-10 V DC @ 500 ohms or higher resistance
- Power Supply: AC/DC Auto sensing wide range supply, PS1 (std) 85-265 VAC / 95-370 VDC @ 2.5W max 4.2W PS2 18-48 VAC / 10-72 VDC @ 2.5W max 4.2W
- Operating Temp.: 0 to 60°C
- Storage Temp: 20°C to 70°C
- Relative Humidity: 95% (non condensing)
- Case Dimensions: 9/64 DIN (Bezel 36Wx144Hmm), Depth behind bezel (5.83") 148mm Plus (0.7) 18mm for connectors
- Weight: 9.5 oz., 12 oz when packed
Face Plate Scales
-
- A standard 0 - 100 scaled face plate, as shown is provided with each meter, or blank face plates may be ordered at no charge. Alternatively a customized face plate with special scaling can be ordered. The price for these face plates will depend on the degree of customization, type of logos required, number of colors used and quantity.



Clear Face Plate Cover
This cover is designed to be dust and water proof to NEMA-4 standards. The lens cover consists of a base and cover with a cam hinge and key-lock locking device.
An O-ring, or Neoprene gasket forms a seal between the base and the panel. The cam hinge holds the cover from closing when opened until pushed closed. A safety catch keeps the cover closed even when the key is removed and the key hole can be used to attach a safety seal clip, preventing unauthorized opening.
|
 |
Panel Adapter
Fits 6 Edgewise Pointer Meter Cut-Outs
The adapter snaps on the 36 x 144 mm case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut-out.
Fits Cut-outs
Width: 44 mm to 45 mm
(1.73) to (1.79)
Height: 143 mm to 145 mm
(5.62) to (5.71)
|
|
 |
|
For ordering information call: 1-800 TEXMATE (1-800-839-6283)
For tech assistance call: (760) 598-9899 Fax: (760) 598-9828
TEXMATE 995 Park Center Drive, Vista, CA. 92083 800-394-8344 www.texmate.com
|
|